Fluke 435 optical cable driver

Unit does not come with the needed drivers or software but both can be obtained from fluke. This fluke product will be free from defects in material and. Sometimes i can find each one of the cables clearly detailing how they support and scopes. Confusion over two types of fluke oc4usb usb interface cables. The new iec standards for flicker, harmonics and power quality are built right in to take the. Installing the usb driver for the fluke 1735 youtube. Pro3000 checking continuity on two conductors of a cable. Versiv usb connection details and troubleshooting fluke. Hopefully i just saved somebodt the 6 hours it took me to figure this out. With the tilt stand folded out, the optical rs232 port can be accessed at the right side of the analyzer as shown in the figure. This may be a good product if i find the drivers to install it.

Hello, i bought a fluke 287 dmm used from uk real cheap and in great condition, but its firmware is the original one and i wanted to update it and maybe try to get some logging data to my computer, since the original fluke cable seems to be just an ordinary usb to ir cable with a custom mounting, and the its price is like 60 way to much for something that simple. Reference guide for testing and troubleshooting fiber. If this is the case, we just need to force if you have checked your connections and still cannot connect your versivtfs main frame to linkware pc, please ensure you do not have a vpn sessionconnection open and that you are running the. Fluke 433434 435 threephase power quality analyzers. Troubleshooting is faster with onscreen display of trends and captured events, even while background recording continues. I have one and everytime i have a fluke 189 cross my desk i lament that i cant metcal it.

This is the only way i was able to download the drivers, i rented the unit and it came without the cd so i did not have a hard copy of the drivers and the link on fluke s website for the drivers seems to be defective. Fluke 985 airborne particle counter firmware update. Page 3 all models include the following accessories tl430 test lead set, 4 x i430 thin flexi current probes, bp290 battery, bc430 power adapter with international power adapter set, usb cable ab mini and powerlog cd. The logger function allows you to configure what measurements you would like to. It is possible that the usblan driver has not been installed for the usb port you are connected to on your pc.

Safetydesigned interface cable to connect the opticallyisolated serial interface port of scopemeter or power quality analyzer to a standard usbinterface on. Testing idc 110 block connections with dsx cableanalyzer. Rated 1 out of 5 by srnickels from does not securely attach does not securely latch onto my fluke 287. Connect your fluke 430 series unit to a computer using the oc4usb or pm9080 cable. The fluke 434 and fluke 435 threephase power quality analyzers help you locate, predict, prevent and troubleshoot problems in three and singlephase power distribution systems. Fluke 805 vibration meter trending template instructions for installing. Windows 7 operation with the fluke optical cable assembly with the fluke oc4usb usb interface cable safetydesigned interface cable to connect the opticallyisolated serial interface port of. These models are referred to throughout this manual as the. This cable is an interface to connect the opticallyisolated serial interface port of a scope meter or power quality analyser to a standard usbinterface on your pc. Installing the new wifi sd card in a fluke 435sii youtube. Compare pricing for fluke fluke435 ii across 18 distributors and discover alternative parts, cad models, technical specifications, datasheets, and more on octopart. To enable the fluke optical cable assembly usb to be operative on. If you used a usb port, under file, select the relevant comport the usb drive. It comes with the i can only assume the marketing words infrared and optical are actually referring to the exact fluke oc4usb technology behind each.

To install the driver, visit and download a vcp driver that is. There is a glitch cather, but that only says if there has been a glitch wider than 8 ns. Once both drivers are installed you should be good to go. Download the latest drivers for your fluke usb devices to keep your computer uptodate. The alignment of the optical board ir detector and diode inside the scopemeter connector f,uke critical. Try import from connected tester, or make sure you chose dsx cable analyzer as the import target. I buy a fluke 434power quality analyzer meter,it can communicated with windows hypterminal but cant receive anything,therefore it cant receive anything by labview also. We appreciate your interest in 64bit usb drivers for dtx, optifiber and cableiq. Fluke 433434435 threephase power quality analyzers fluke. Product firmware, software upgrades and standalone applications. The usb drivers are contained in the full standalone installer for the program. Fluke oc4usb driver for windows drivers from core zeam. Installing the usbir cable drivers xp or windows 2000. A restart of the pc after the new installation is also recommended.

The 189 cal manual makes me think there is another peice of software i might be missing. Optical isolation allows you to float your instrument at mains voltages or beyond, while bing connected to your pc. How to transfer data from the fluke 435 to the power log. Fluke networks otdr port saver test reference cords are short 0. Safetydesigned interface cable to connect the opticallyisolated serial interface port of scopemeter or power quality analyzer to a standard usb. Fluke networks launch cables for optifiber pro otdr. The pm9080101 is an optically isolated rs232 adapter, safety designed serial interface for digital hardcopy output to serial printer or remote control via a pc. Optical isolation allows you to float your instrument at mains voltages or beyond, while. I have noticed there are two types of fluke oc4usb usb interface cables. In this video, youll learn how to perform a windows 7 operation with the fluke optical cable assembly. In this video, youll learn how to transfer data from the fluke 435 ii power quality and energy analyzer to the compatible. Sometimes the one in the first picture is also marketed as ir infrared oc4usb whilst the last one is marketed as optical. In this video, youll learn how to install the usb driver for the fluke 1735 power logger. Then i find a vague interace oc4usb usb interface cable a fluke website where one member mentions revision 1 and revision 2, but never actually explicitly details nor supplies any pictures as references.

In this video, learn how to perform a logger setup on the fluke 435 power quality and energy analyzer. Fluke 805 vibration meter firmware and trending template. I have the ir readers driver installed and it registers on com4 but metcal cant seem to query it. Fluke usb devices drivers download for windows 10, 8. Pm9080101 fluke test accessory, optically isolated.

The fluke 435 ii power quality and energy analyzer includes the same great features of the 434ii while adding advanced power quality functionality for more in depth troubleshooting. Using the new wifi sd card of a fluke 435 sii is really very convinient as it is possible to connect the pc to the wifi generated by this sd card and in this way we can download files from the. Fluke 435 optical serial cable data transfer tutorial youtube. Fluke 434ii 435 ii437ii three phase energy and power quality analyzer hereafter. Power log the software is the pc software for fluke 345, 433, 434, 434ii, 435, 435 ii, 437ii, vr1710 and 1735.

Dear man, nice tutorial, i am having the similar issues with scopegrab32 on windows xp. Fluke networks otdr port saver test reference cords. Three phase energy and power quality analyzer users manual en. Fluke 805 vibration meter trending and printing instructions. Download fluke 435 power quality analyzer firmware 2. Optical isolation allows you to float your instrument at mains voltages or beyond, while being connected to your pc. If you need the same advanced functionality as the 435 ii a higher frequency, the fluke 437ii is the musthave power quality analyzer for 400 hz power systems. This is the newbie category of the forum blog for a reason. Technical specifications specifications are valid for models fluke 434ii, fluke 435 ii, fluke 437ii unless otherwise specified. Fluke 434 435 power quality and energy analyzers fluke. How to communicate with fluke 434 power quality analyzer. Due to increased complexity of cabling systems, determining the cause of failure and quickly restoring suitable performance can be. Once power log is fully uploaded, you can now access the data generated by the fluke 435. September 28, you need to hold the optical end at the right spot over the scope fluke oc4usb.

Fluke networks optical fiber test and troubleshooting quickreference guide is a handy document for users of the companys fibertest tools. Im not sure if the problem is with the 287 ir port or the ir189usb. Additionally, the fluke patented energy loss algorithm, unified power measurement, measures and quantifies energy losses fluke 435 usb flule harmonics and unbalance issues, allowing the user to. Both of these cables are marketed as oc4usb at times. Powerlog classic application software used with the fluke 345, vr1710, 1735 and 433434435.

Fluke ii series of power quality analyzers fluke corporation. Windows 7 operation with the fluke optical cable assembly. In this quick tutorial, i show how to transfer data setsreports off of a fluke 435 power quality analyzer using a serial cable rather than the. Fluke 43b singlephase power quality analyzer software downloads. The driver for the fluke device is on the cd supplied with the instrument. When asked, select save to save the software update on your hard disk. Powerlog software, and usb drivers 10 usb interface cable for pc connection usba to miniusbb 11. And scopegrab is only for linux, any proposal to use higher transfer rate.

255 686 753 28 1260 667 1339 216 51 852 412 309 1233 1219 540 200 937 605 32 736 715 1226 787 159 58 497 1355 88 53 662 36 995 246 747 1137